Ultrasonic Flowmeter Uses Two Independent Fiscal Flow Measurements

Transus Instruments’ UIM-4F Duo ultrasonic flowmeter consists of two independent fiscal flow measurements in a single flowmeter body, enabling enhanced condition-based diagnostics in a compact package. Primary measurement is accomplished by a four-path system while an independent, concurrent three-path system provides secondary measurement for extensive diagnostic information using TIMCare software.

 

The primary flow measurement uses the UIM-4F four path chordal configuration, meeting AGA Report No. 9 and OIML R137 (class 0.5) international standards for custody transfer metering. The secondary flow measurement uses the company’s UIM-3F three path chordal configuration, also highly accurate, and meeting AGA Report No. 9 standards.

Free Newsletter

Like this article? Subscribe to FierceSensors!

The sensors industry is constantly changing as innovation runs the market’s trends. FierceSensors subscribers rely on our suite of newsletters as their must-read source for the latest news, developments and analysis impacting their world. Register today to get sensors news and updates delivered right to your inbox.

 

Available in sizes of 8 inches and larger with flange ratings up to 900 pounds, the fiscal flow measurement system provides continuous verification by use of the secondary measurement. It is a highly economical solution when a redundant measurement is required for monitoring and verification, allowing smaller skid sizes and lower installation costs.

 

Traditional arrangements use a secondary measurement with single or dual paths, often resulting in an overly sensitive system that can cause false indications of fouling or flow conditioner blockages. By using a three-path secondary measurement, which is less sensitive to slight profile changes, the UIM-4F Duo provides the diagnostics needed to detect potential issues without giving false alarms. The UIM-4F Duo path layouts are oriented at different chord locations eliminating common mode errors as both meters respond differently to profile changes.

 

Transus Instruments’ ultrasonic transducers operate at very low transmitting voltages, allowing the UIM-4F Duo to be certified Intrinsically Safe by DEKRA. For more information, visit Transus Instruments and/or email [email protected].

Read more on